-40%

Kane 5-Gas HC O2 CO CO2 NOX Automotive Diagnostic Exhaust Gas Analyzer

$ 2373.35

Availability: 98 in stock
  • Manufacturer Part Number: ANSED/KANE-EGA5
  • Condition: New
  • Brand: Kane

    Description

    Feel confident in your purchase, we're an
    Authorized Kane Dealer
    . How cool is that?!
    IMPORTANT
    (read before buying):
    -This equipment is for use by professionals. Make 100% sure you understand what you're buying. If you have questions ask.
    -No Returns are accepted. However, the item will be full covered by the warranty.
    Features:
    Tests HC, O2, CO, CO2, NOX and Lambda.
    Readings are LIVE. (
    except NOx and LAMBDA which are calculated).
    Detect problems too marginal to be detected by an onboard computer or scan tool.
    Interprets the exhaust gases & their interactions.
    Provides a top-down list of suggested problems and solutions in order of probability.
    Reduce diagnostic time, verify repairs are complete, reduce comebacks, and increase overall profitability and customer satisfaction.
    Self-calibrating, no cal-gas required.
    Dyno not required for NOX testing.
    Completely portable.
    Low cost to operate and maintain.
    Operates off internal rechargeable battery.
    Water trap and filter visible.
    Display: Large and easy to read all gases and Lambda on one screen, no scrolling
    Ergonomic Design Keypad: Simple and easy to navigate and use.
    Bluetooth or USB Cable ready: Links analyzer easily to PC to use with KANE LINK.
    Variable Pump Speed: Allows for adjustment of the pump speed, which can then improve battery life
    Optional Hi-Speed Print Capability: Use with the hi-speed printer with rechargeable battery. (not included)
    Probe: Equipped with the EP1 Hi-Temperature Probe, with Neoprene tubing and a
    350mm insertion depth
    .
    The Kane 5-Gas Automotive Diagnostic Exhaust Gas Analyzer allows you to quickly and easily diagnose vehicle issues through exhaust gas. It's perfect for diagnosing performance, drivability, no code, and catalytic converter issues as well as other problems that most scanners & onboard computers cant. The EGA5 even offers suggestions on how to repair these issues. It's the most comprehensive and complete exhaust gas analyzer on the market today!
    Technical Specifications:
    Parameter
    Resolution
    Accuracy
    Range
    Carbon Monoxide
    (High Range NDIR)
    0.01 %
    +/- 5 % of reading
    *1
    0-10 %
    Oxygen
    0.01 %
    +/- 0.3 % volume
    *1
    0-25 %
    Hydrocarbon
    (NDIR)
    1 ppm
    +/- 5 % of reading
    *1
    +/- 12 ppm volume
    *1
    0-5000 ppm
    Over-range: 10,000 ppm
    Carbon Dioxide
    (NDIR)
    0.1 %
    +/- 0.3% of reading
    *1
    0-20 %
    Nitric Oxide*²
    (fuel cell)
    1 ppm
    0-1500ppm +/-5% or 25ppm;
    0-5000ppm
    Carbon Monoxide
    Corrected COK
    0.01%
    Calculated
    0-15%
    Lambda
    AFR (Petrol)
    (LPG)
    0.001
    00.01
    0.8 – 1.2
    11.76 – 17.64
    12.48 – 18.72
    Sensor response Time
    Nominal 20 seconds
    Warm up
    Less than 2 minutes
    Pre-programmed Fuels
    Petrol/Gasoline, LPG Diesel and CNG.
    PC connection
    Via RS 232 port
    Data-Logging
    200 Tests
    Dimensions
    Weight
    Handset
    Probe
    1.2 kg (2.65 pounds)
    240mm x 165mm x 65mm (9.45 x 6.5 x 2.56”)
    Insertion depth 350mm x Diameter 15mm
    Clip handle to secure to exhaust, 4m long hose
    Various probes available including high temperature
    Ambient Operating Range
    +5
    °
    C to +50
    °
    C / 10% to 90% RH non-condensing
    Storage temperature
    Minimum: 0
    °
    C
    Maximum: +45
    °
    C
    Battery Charger
    Input:
    100-240 V
    Output:
    12 V DC
    Analyzer battery run time
    6+ hours from full charge.
    ANSED Exhaust Gas Diagnostic Software:
    Interprets the exhaust gas analyzer readings in seconds!
    Uses a floating matrix formula for each gas reading, coupled with other diagnostic variables, to enhance the accuracy.
    Several possible solutions, in order of probability, are suggested with the first one the likely cause in 80% of the situations.
    Diagnose no-code drivability & performance issues
    Ensure catalytic converter related repairs are complete
    Print test results reports: pre- and post-repair (printer not included)
    Verify vehicle running at max efficiency after repairs and prevent comebacks
    Easy-to-read PASS/FAIL report.
    Pre-repair reports provide initial gas analysis for review.
    Customer Report offers a “customer friendly analysis” of the exhaust diagnostic test.
    Technician Report details the diagnostic test results and suggested procedures.
    Post-repair report verifies that repairs have been completed and the vehicle is running at maximum efficiency.
    All reports can be printed or saved for future reference. (Printer not included)
    What's Included?
    KANE-EGA5 5-Gas Analyzer
    EP1 Hi-Temp Probe
    CU12VDC2A21 AC Charger
    CA10733/4 12V In-Vehicle Charger
    PF2/5 Replacement Filters (pack of 5)
    User Manual & Quick Start Guide
    ANSED Exhaust Gas Diagnostics Software (FREE)
    KANE LINK wireless module
    CL5 USB Cable
    14102/2 Shoulder Carry Bag